.. 1AXES01 5101 0001 1AX0179 2950 R03M00 0001 ., PTF ID . . . . . . . . . . . . . . . . : 1AX0179 PRODUCT ID . . . . . . . . . . . . . . : 1AXES01 RELEASE . . . . . . . . . . . . . . . : V1R3M0 OPTION . . . . . . . . . . . . . . . . : 0001 LOADID . . . . . . . . . . . . . . . . : 5101 PTF OBJECT LIBRARY . . . . . . . . . . : AXES PREREQUISITE PTFS PTF ID PTF ID PTF ID PTF ID 1AX0141 *COREQ DESCRIPTION OF PROBLEM FIXED: ----------------------------- WHEN A PANEL CONTAINING DBCS DATA IS ACTIVE AND IS SUSPENDED BY THE DISPLAY OF ANOTHER PANEL (SUCH AS VIA THE ATTENTION KEY) AXESTS INCORRECTLY PARSES THE DBCS DATA STREAM. THIS CAN CAUSE INCORRECT CHARACTERS TO BE DISPLAYED WHEN THE ORIGINAL PANEL IS RESTORED. CORRECTION: ----------- AXESTS WAS NOT SAVING THE STATE OF DBCS TEXT THUS CAUSING DBCS TEXT TO BE INTERPRETED AS IF IT WERE SBCS TEXT. AXESTS NOW CORRECTLY SAVES THE STATE OF DBCS TEXT. THIS PTF CORRECTS THE DEFECT. CIRCUMVENTION: -------------- NONE. ACTIVATION INSTRUCTIONS: ------------------------ NONE. SPECIAL INSTRUCTIONS: --------------------- END THE AXES SERVERS BEFORE APPLYING THIS PTF. ******************************************************************** THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED, IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN. ******************************************************************** SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF 1AX0142: ------------------------------------------------ PTF 1AX0141 MUST BE APPLIED BEFORE THIS PTF TAKES EFFECT. DEFAULT INSTRUCTIONS: --------------------- THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED. SUPERSEDED PTFS PTF ID PTF ID PTF ID PTF ID 1AX0170 1AX0142